View a printable version of this section (PDF)Engineered from 100% solution dyed fibers, our Acoustical Collection wall fabric is needlebonded into a continuous structure, then finished with a heatset, latex back to ensure fiber lock. Designed to be soft and flexible as well as acoustically absorbent, but still hold up well in high-traffic areas. By nature it is "self healing", making it ideal for Tackable walls. Velcro compatible.
The Niagara IV line is made with recycled content, providing an enivronmentally friendly option in addition to its other advantages.
Specifications:
The Helderbergs IV | The Niagara IV | |
---|---|---|
Properties: | Needlebond | Needlebond |
Pattern: | Single Rib | Single Rib |
Fiber: | Solution Dyed OLEFIN | Solution Dyed PET Blend |
Total Weight: | 28½ oz/lineal yard | 30 oz/lineal yard |
Roll Size (WxL): |
54" x 24 lineal yards | 54" x 24 lineal yards |
Packaging: |
Boxed: Crush Warranty |
Boxed: Crush Warranty |
Acoustical Properties:
ASTM C-423-84A | The Helderbergs IV | The Niagara IV |
---|---|---|
Gypsum Board | NRC .25 | NRC .20 |
Acoustic Board | NRC .65 | NRC .60 |
Abrasion:
TR-609 Severe Random Tumble |
The Helderbergs IV | The Niagara IV |
---|---|---|
Pill | Moderate | N/A |
Fuzz | Slight | N/A |
Colorfast:
AATCC-165 | The Helderbergs IV | The Niagara IV |
---|---|---|
Wet Crocking | 5; No Stain | 5; No Stain |
Dry Crocking | 5; No Stain | 4-5; Slight Stain |
Electrostatic:
AATCC-134 | The Helderbergs IV | The Niagara IV |
---|---|---|
Propensity |
0.1 kilovolts |
0.2 kilovolts |
Acoustical Wallcovering Flammability
View a printable version of this section (PDF)General:
- Acoustical Wallcovering flammability requirements very significantly.
- Application, substrate, location, sprinkler system and end use of the room all contribute to the requirements.
- It is highly recommended that direct contact be made with the local fire marshal prior to installation to ensure compliance with local codes.
The Niagara IV:
- Passes the National Fire Prevention Association 265 (NFPA"265) test.
- Passes the UBC 8"2 Corner Burn Test, formerly UBC 42.2 and modeled after the “Pheonix” Corner Burn test.
- Class A rated when tested in accordance with ASTM E"84, commonly referred to as the Tunnel Test or “Steiner” Tunnel Test.
- Care should be taken not to get adhesive on the face. If adhesive lands on the face of the material, check with the adhesive manufacturer.
The Helderbergs IV:
- Class A rated when tested in accordance with ASTM E"84, commonly referred to as the Tunnel Test or “Steiner” Tunnel Test.
Please Note:
The above is based upon independent laboratory testing. At the time of delivery, the product shall be of the quality and specification stated herein without any other warranty, expressed or implied. Any recommendation made concerning use or application of above products is believed to be reliable and any implied warranty for a particular purpose is expressly excluded. If the product does not meet the current published specification at the time of sale and the customer gives notice prior to installation, then the product will be replaced. All returns must be made with prior Return Authorization Number, subject to a 30% restocking fee and completed within 30 days of shipping.